The PanelView Plus 6 (PV+6) Terminal is a series of advanced human-machine interface (HMI) devices designed to streamline processes, enhance productivity, and provide intuitive interaction within industrial environments. Boasting a myriad of features and highlights, the PV+6 Terminals stand as a testament to Rockwell Automation’s commitment to innovation and excellence in industrial automation.
PanelView Plus 6 configuration for Allen-Bradley SLC 5/04 & PLC-5 Datahighway Plus (DH+) communications with ANC-100e
This document provides information to configure a Panel View Plus to communicate with
SLC5/04 or a PLC5 on a DH+ network with an ANC-100e Ethernet to Data Highway Plus
converter.
Note: Before proceeding, make sure
โ ANC-100 is properly connected to the DH+ and Ethernet networks
โ Network adapter of PanelView is correctly configured to access ANC-100e
For this example:
*ANC-100e IP address = 192.168.0.230
*You could use a SLC 5/05,5/04 or PLC 5/40 and the IP address could be =
192.168.0.70
โขโ โ Node address = 12
1.โ โ Open ANC-100e web interface.
2.โ โ Go to the โHMIโ tab and submit the next information. Then click โApplyโ
PanelView Plus 6 DH+ messaging with ANC-100e Application note
Panelview Plus 6 (PV+6) Terminal Features
1. High-Resolution Touchscreen Displays
At the heart of the PV+6 Terminal lies their high-resolution touchscreen displays, which offer crisp visuals and responsive touch functionality. Available in various sizes ranging from compact to widescreen, these displays provide operators with clear, detailed views of processes, equipment status, and control options. Whether navigating complex control systems or monitoring critical parameters, the PV+6 touchscreen displays ensure optimal visibility and ease of use.
2. Versatile Communication Options
One of the key highlights of the PV+6 Terminal is their versatility in communication options, allowing seamless integration with a wide range of industrial automation systems. With support for Ethernet/IP, serial, and USB connections, as well as compatibility with major PLC and controller platforms, the PV+6 Terminals enable effortless communication and data exchange across diverse industrial networks. This flexibility not only simplifies system integration but also enhances interoperability and scalability, making the PV+6 Terminals ideal for both standalone and networked applications.
3. Enhanced Performance and Processing Power
Equipped with powerful processors and ample memory capacity, the PV+6 Terminal deliver enhanced performance and processing power to meet the demands of modern industrial environments. Whether running complex applications, handling large datasets, or executing real-time control tasks, the PV+6 Terminals ensure smooth operation and rapid response times, thereby optimizing productivity and minimizing downtime. Additionally, advanced graphics capabilities enable dynamic visualization of processes and data, enhancing operator situational awareness and decision-making.
4. Robust Design and Durability
Built to withstand the rigors of industrial environments, the PV+6 Terminal feature a robust design and durable construction that ensures reliable performance in harsh conditions. With ruggedized enclosures, sealed touchscreen displays, and industrial-grade components, the PV+6 Terminals offer protection against dust, moisture, vibration, and temperature extremes, making them suitable for a wide range of industrial applications, from manufacturing plants to oil and gas facilities. Moreover, compliance with industry standards for environmental resilience and electromagnetic compatibility further underscores the reliability and durability of the PV+6 Terminals.
5. Intuitive Software and Programming Tools
Facilitating seamless configuration, programming, and maintenance, the PV+6 Terminals are supported by intuitive software and programming tools that simplify HMI development and customization. With Rockwell Automation’s Studio 5000 View Designer software, users can easily create and deploy customized HMI applications, incorporating interactive graphics, alarms, trends, and navigation features. Furthermore, support for industry-standard protocols such as OPC-UA enables seamless integration with third-party software and systems, enhancing interoperability and flexibility.
6. Comprehensive Security Features
In an era of increasing cyber threats, security is a top priority for industrial automation systems. Recognizing this imperative, the PV+6 Terminals incorporate comprehensive security features to safeguard critical assets and data against unauthorized access, tampering, and malware attacks. From user authentication and role-based access control to data encryption and secure communication protocols, the PV+6 Terminals provide multiple layers of defense to mitigate risks and ensure the integrity and confidentiality of industrial operations.
Highlights
Feature | Description |
---|---|
High-Resolution Touchscreen Displays | Crisp visuals, responsive touch functionality, and various display sizes for optimal visibility and ease of use. |
Versatile Communication Options | Support for Ethernet/IP, serial, and USB connections, as well as compatibility with major PLC and controller platforms for seamless integration. |
Enhanced Performance and Processing Power | Powerful processors, ample memory capacity, and advanced graphics capabilities for smooth operation and rapid response times. |
Robust Design and Durability | Ruggedized enclosures, sealed touchscreen displays, and industrial-grade components for reliable performance in harsh industrial environments. |
Intuitive Software and Programming Tools | Studio 5000 View Designer software for easy configuration and customization, support for industry-standard protocols, and third-party integration. |
Comprehensive Security Features | User authentication, role-based access control, data encryption, and secure communication protocols to mitigate cyber threats and ensure data integrity. |
In conclusion, the PanelView Plus 6 (PV+6) Terminals represent a pinnacle of industrial human-machine interaction, offering a comprehensive suite of features and highlights designed to enhance efficiency, reliability, and security in industrial automation applications. With their high-resolution touchscreen displays, versatile communication options, enhanced performance, robust design, intuitive software, and comprehensive security features, the PV+6 Terminals empower operators to control, monitor, and optimize industrial processes with confidence and ease.
PanelView Plus 6 DH+ messaging with ANC-100e Application note
The ANC-100e DH+ converters provide communications between newer Ethernet Technologies and DH+ legacy PLC-5s and SLC/504s
The ANC-100e is a pocket-sized, high performance, Industrial Rated Ethernet DH+ Converter. Features include: Ease of Configuration via Web Interface and DH+ Auto Polarity Detection and DH+ Auto Baud Rate Detection.
$1,295 USD List.
20 min. theautomationblog review.
Data Highway Plus to Ethernet (S02)
In todayโs episode of The Automation Show, I unbox and setup an ANC-100E Data Highway Plus to Ethernet bridge from Automation Networks. For more information about the show (and how you could win an ANC-100E) check out the โShow Notesโ located below the video. The Automation Show, Episode 2 Show Notes: NOTE: Would you like your โฆ Continue readingData Highway Plus to Ethernet (S02)
The ANC-120e is a competitive alternative to ABโs 1784-U2DHP PLC Programming Cable
s an economical and high performance USB-to-Allen-Bradley Data Highway Plus converter interfacing major HMI, SCADA, PLC Programming packages to Devices on DH+. Its features significantly outperform ABโs 1784-U2DHP PLC Programming Cable operating at 12 Mg USB speed with the Controllogix Ethernet/IP Driver.
The ANC-120e works with all SCADA, MMI, PLC programming packages installed on your PC with USB direct access to the DH+ network and stations. These packages include RSLINX/LOGIX Classic & Enterprise with RSLOGIX 5/500, Wonderware DAServer & TCP/IO Server, Citect, and Kepware using Controllogix Ethernet/IP Drivers.
$1,295 USD List.
In todayโs episode of The Automation Podcast I take a look at the ANC-120e USB to Data Highway Plus converter from Automation Networks. Now you may be asking yourself why the folks over at Automation Networks would release a USB to DH+ converter when Rockwell already makes the 1784-U2DHP? Well if you havenโt looked lately, that โฆ Continue readingUSB To Data Highway Plus (DHP, DH+) โ Using the ANC-120e, a lower cost alternative to the 1784-U2DHP