Modbus to OPC UA converter

In the heart of countless industrial automation systems, Modbus reigns as a reliable, ubiquitous communications protocol. Yet, as factories adopt Industryโ€ฏ4.0, Edge computing, and cloud integration, OPCโ€ฏUA has emerged as the modern, secure, and semantically rich backbone for data exchange. The challenge? So many existing Modbus installationsโ€”on PLCs, RTUs, HMIs, and field devicesโ€”canโ€™t speak OPCโ€ฏUA natively.

Enter the Modbus-to-OPCโ€ฏUA converter: a gateway that translates between these protocols, allowing Modbus devices to seamlessly participate in modern OPCโ€ฏUA ecosystems without costly overhauls. This article explores their mechanics, benefits, configuration, applications, and future outlook in depth.

Modbus to OPC UA converter

Why Bridge Modbus to OPCโ€ฏUA

Legacy Device Ecosystem

Thousands of devicesโ€”from Schneider, Siemens, Allenโ€‘Bradley, ABBโ€”rely on Modbus RTU or TCP. Converters allow continued use of these systems, preserving investment.

Security & Modern Standards

Modbus lacks encryption or authentication. OPCโ€ฏUA provides TLS encryption, certificate-based authentication, and robust access control, essential for secure IIoT. Semantic Data Modeling

Modbus uses flat address spaces (coils, registers). OPCโ€ฏUA structures data in an object-oriented address space with metadata, relationships, methods, and eventsโ€”ideal for digital twins, analytics, and smart factories.

Bridging OT to IT

OPCโ€ฏUA facilitates integration with MES, ERP, cloud platforms (Azure IoT, AWS, Google Cloud, Predix) using standards like MQTT, AMQP, REST APIsโ€”transforming OT data into actionable insights.

Anatomy of a Modbusโ€“OPCโ€ฏUA Converter

A converter typically comprises:
โ€ข Dual protocol stacks: Modbus RTU/TCP + OPCโ€ฏUA server
โ€ข Network interfaces: Serial (RSโ€‘485, RSโ€‘232) for Modbus RTU; Ethernet for TCP and OPCโ€ฏUA
โ€ข Data mapping engine: Maps Modbus addresses to OPCโ€ฏUA nodes/variables
โ€ข Security manager: Handles TLS, certificates, user authentication for OPCโ€ฏUA
โ€ข Configuration interface: Web GUI or desktop tool for mapping, networking, security
โ€ข Diagnostics & logging: Provides health, polling, performance, and error visibility
โ€ข Edge capabilities (optional): Local scripting, data aggregation, buffering, cloud forwarding

Converters come in various forms:
โ€ข DINโ€‘rail hardware gateways: Rugged, industrial-grade with serial and Ethernet ports
โ€ข Embedded edge devices: Industrial PCs, box PCs
โ€ข Software-only solutions: Installed on Windows, Linux, Docker, VM

Core Features & Requirements

When choosing or implementing a converter, key considerations include:

Protocol Support
โ€ข Modbus RTU: RSโ€‘485 serial, configurable baud rates, even/odd parity
โ€ข Modbus TCP: Standard Ethernet-based communication
โ€ข OPCโ€ฏUA Server: Support for UAโ€‘TCP, HTTPS, secure sessions, and Pub/Sub (optional)

Data Mapping & Modeling
โ€ข Map coils/registers to types: Boolean, Int, Float, etc.
โ€ข Use structured modeling: e.g., โ€œPump1.Speed,โ€ โ€œConveyor.Statusโ€ with metadata
โ€ข Group variables using OPCโ€ฏUA Objects and Types, organize in Namespaces
โ€ข Handle multi-register values (e.g., 32โ€‘bit or 64โ€‘bit floats, multiple coils)

Security
โ€ข Manage X.509 certificates and trusted peers
โ€ข Enable TLS encryption and signing policies
โ€ข Configure user accounts and access roles

Performance & Scalability
โ€ข Poll Modbus devices cyclically or on-demand
โ€ข Optimize polling frequency and queue size to minimize latency
โ€ข Support batching and bulk read/write to improve throughput
โ€ข Scale to hundreds or thousands of mapped variables

Diagnostics & Reliability
โ€ข Provide health/status endpoints, logs, and alarms
โ€ข Support failover or redundancy for high-uptime requirements
โ€ข Offer buffering for disconnected conditions (offline mode)

Ease of Use
โ€ข User-friendly configuration via web tools or desktop clients
โ€ข Export/import configurations for reproducibility
โ€ข Device discovery and Modbus address scanning

Edge & Cloud Readiness
โ€ข Optional MQTT/REST bridge for cloud-forwarding
โ€ข Local scripting (e.g., JSON transformation, calculations, thresholds)
โ€ข OPCโ€ฏUA Pub/Sub enables multicast, edge-network connectivity

Configuring & Using a Converter

Setup Overview
1. Connect to Modbus via serial or TCP settings
2. Enable OPCโ€ฏUA Server on an Ethernet port, configure endpoint URL, security mode, user policies
3. Load or scan Modbus registers and coils automatically
4. Map each Modbus address to an OPCโ€ฏUA node in the workspace
5. Test connectivity using OPCโ€ฏUA client (UaExpert, Matrikon, Prosys)
6. Deploy to production with monitoring enabled

Mapping Walkโ€‘Through
โ€ข Example: Map Modbus holding register 40001 โ†’ OPCโ€ฏUA node โ€œPump1.Speedโ€ (Float)
โ€ข Configure datatype conversion (16-bit INT to float), scaling, unit metadata
โ€ข Tag multiple Modbus registers with prefixes (e.g., โ€œ400xx Motor Camโ€)

Securing Connections
โ€ข Generate CA-issued or self-signed server certificate
โ€ข Approve client certificates dynamically (UaExpert, SCADA)
โ€ข Enforce TLS and signing via minimum โ€œBasic256Sha256โ€ profile
โ€ข Create user accounts (username/password, token-based, or role-based)

Monitoring & Maintenance
โ€ข Use embedded dashboard for CPU, uptime, connection health
โ€ข View real-time data points and Map/Unmap variables live
โ€ข Export logs for traceability; set up SNMP or OPC-UA alarm events Advanced Patterns
โ€ข Event-based mapping: map Modbus coils as OPC-UA variable with subscription
โ€ข Edge scripting: apply logic, thresholds, event filtering
โ€ข Cloud forwarding: configure MQTT broker and topic settings for telemetry
โ€ข Redundancy cluster: Active/backup converter setup

Real-World Applicatio

Manufacturing
โ€ข Production line with legacy Modbus devices connects to OPC-UA SCADA
โ€ข Speeds data feed to ERP/MES using structured information models
โ€ข Enables predictive maintenance dashboards and OEE monitoring

Water/Wastewater
โ€ข RTUs on pumps and valves use Modbus RTU; converter aggregates data
โ€ข OPC-UA server standardizes access for utilities management software
โ€ข Event alarms trigger notifications for leaks or failuresHVAC in Smart Buildings
โ€ข Modbus thermostats and meters feed into OPC-UA building management systems
โ€ข Enables centralized control of HVAC, lighting, energy analytics

Energy / Substation Automation
โ€ข Modbus-based IEDs relay status and measurement data to OPC-UA SCADA
โ€ข Cloud analytics (demand response) and cybersecurity alerts run using OPC-UA endpoint

Oil & Gas
โ€ข Field devices using Modbus loop back data to control room
โ€ข Harmonized alarm, control, and historian logging through OPC-UA-integrated systems

Challenges and Strategic Considerations

Flat Modbus vs. Structured OPCโ€ฏUA
โ€ข Manual modeling is needed to align flat registers to OPC-UA data classes
โ€ข Leverage code generation or companion specs to standardize models

Latency Constraints
โ€ข Excessive polling or batching can increase delays
โ€ข Use tuning: selective polling, Pub/Sub if scalability matters

Modbus Stretch
โ€ข Modbus has limits: 65k registers per slave, 1k coils; monitor boundaries
โ€ข Segment data and map across multiple devices if needed

Security
โ€ข Exposing a Modbus network via an OPC-UA gateway means securing both ends
โ€ข Protect serial or TCP networks with VLANs, firewalls, VPN

Maintenance Lifecycle
โ€ข Firmware updates must be managed thoughtfully
โ€ข Monitor certificate lifetimes and manage renewals

Leading Vendors & Solutions

Vendor / Solution
Type
Notable Features
Matrikon OPC Tunneller / OPC UA DA
Software for Windows
Supports scaling, redundant servers
Kepware KEPServerEX (Modbus to OPC UA)
Windows software
Flexible mapping, MQTT plug-in, REST add-ons
Softing uaGate MBX
DINโ€‘rail gateway
Compact, robust, supports RTU/TCP, secure OPC UA
HMS Anybus Mโ€‘gateway
DINโ€‘rail hardware
Redundant, Modbus TCP/RTU to OPC UA, cloud-ready
Prosys OPC UA Embedded
SDK / Linux edge device
Integrates into Linux appliances, custom converters
open62541โ€‘based custom solution
Developer-built
Openโ€‘source, flexible, highly customizable

Future Landscape
โ€ข Modbus over TSN or time-synchronous extensions may appear
โ€ข Dynamic data modeling via companion specs to reduce manual mapping
โ€ข Edge-enhanced converters with analytics, caching, and AI
โ€ข Autoโ€‘configuration tools may inspect Modbus devices and generate OPCโ€‘UA models automatically
โ€ข Cybersecurity standards evolution to validate converters for OTโ€‘level security and certification

Conclusion

Modbus-to-OPCโ€ฏUA converters are central to bridging legacy industrial assets with modern, secure, and semantically rich systems. They preserve existing investments while enabling access to cloud services, analytics, and smarter control. By providing protocol translation, secure wrapping, structured data mapping, and edge intelligence all in one device or software, these converters are indispensable in digital transformation journeys.

Whether deployed in factories, substations, smart buildings, or process industries, the right converterโ€”not only technically capable but secure, scalable, and maintainableโ€”unlocks long-term value, safety improvements, and deeper system visibility.

ANC-300e: Ethernet/IP & Modbus TCP to Serial Modbus RTU, DF1 Converter
The ANC-300e has the combined performance as an Ethernet and RS-485 serial converter. The gateway behaves like a protocol converter/translator that allows difficult data interchanges and connections between incompatible networks. Protocols include:

RS485 serial Protocols:
Modbus RTU, Modbus Sniffer, A.O. Smith AIN, A.O. Smith PDNP, BACnet MS/TP Client, BACnet MS/TP Server, TCS Basys Master, MSA Chillgard Monitor, DMX 512-Master, DMX-512 Slave, M-Bus Master, Metasys N2 Master, Metasys N2 Slave, Siemens FLN Master, Siemens FLN Slave, Sullair Master, Toshiba ASD Master, Toshiba PLC Master, DF1.

Ethernet Protocols:
Ethernet/IP Client/Server, AB CSP Ethernet Client/Server, Modbus TCP/IP, Profinet IO, BACnet/IP BBMD, BACnet/IP Client, BACnet/IP Server, Baumer VeriSens Client, CC-Link IE SLMP Client, MELSEC Client/Server, Generic Socket Client/Server & GreenFumeHood Client, Modbus TCP.

ANC-300e is an easily configurable Ethernet / RS-485 converter gateway, that provides integrated communication between all the above common industrial and commercial communication networks. As part of the ANC Gateway Converter Series, the ANC-300e provides a common platform which is convenient and easy to setup in all products.

The Automation Network ANC-300e Ethernet & Fieldbus Gateway Converter allows data to be seamlessly transferred between Ethernet to Ethernet and Ethernet to RS-485 networks with simple configuration.

Coming Soon: Need to get data from your EtherNet/IP or Modbus TCP/IP-based devices to your OPC UA clients? This ANC-300e additional functionality is coming shortly.

Data Highway Plus to Ethernet (S02)

In todayโ€™s episode of The Automation Show, I unbox and setup an ANC-100e  Data Highway Plus (DH+) to Ethernet Converter Data Highway Plus to Ethernet bridge from Automation Networks. For more information about the show (and how you could win an ANC-100E) check out the โ€œShow Notesโ€ located below the video. The Automation Show, Episode 2 Show Notes: NOTE: Would you like your โ€ฆ Continue readingData Highway Plus to Ethernet (S02)

The Automation Blog

ANC-100e Ethernet IP to AB's DH+ Converter

The Automation Networks ANC-100e communicates with all SCADA, HMI, PLC programming with direct Ethernet/IP access to the DH+ network and stations.ย 

ANC-100e has similar replacement features as the Controllogix 1756-DHRIO / 1756-ENBT, and AB 1784 Interface Cards: 1784-U2DHP, 1784-KTx, 1784-PKTx, 1784-PCMK and Prosoft AN-X2-DHRIO Converters.

$1,195 USD List.

Overnight Shipping Available

ANC-120e USB to AB's DH+

The ANC-120e is an economical and high performance USB-to-Allen-Bradley Data Highway Plus converter interfacing major HMI, SCADA, PLC Programming packages to Devices on DH+. Its features significantly outperform ABโ€™s 1784-U2DHP PLC Programming Cable operating at 12 Mg USB speed with the Controllogix Ethernet/IP Driver.

Theย ANC-120e works with all SCADA, MMI, PLC programming packages installed on your PC with USB direct access to the DH+ network and stations. These packages include RSLINX/LOGIX Classic & Enterprise with RSLOGIX 5/500, Wonderware DAServer & TCP/IO Server, Citect, and Kepware using Controllogix Ethernet/IP Drivers.ย 

$995 USD List.

Overnight Shipping Available

Glossary Menu

Scroll to Top