ANC-120e USB to DH+ PLC Programming Cable
The ANC-120e converter is the premier USB to Data Highway Plus (DH+) programming cable. Therefore, it is the ultimate 1784-U2DHP alternative for replacing legacy Allen-Bradley interfaces. Specifically, it is designed for seamless connectivity between modern PCs and legacy DH+ networks. Consequently, you can program and monitor controllers without downtime. Indeed, this saves valuable time.
Key Technical Advantages of the ANC-120e Converter:
- Superior Replacement: It is a compact, high-speed USB interface replacing obsolete PCMCIA cards. Furthermore, it easily fits in your pocket.
- Streamlined Setup: Because it requires a simple Windows USB driver, setup is fast. Moreover, the ANC-120e converter connects seamlessly using the “Remote Devices via Linx Gateway” driver. Therefore, it completely eliminates complex routing software.
- Intelligent Auto-Detection: Firstly, it automatically detects default baud rates. Secondly, it also detects auto-polarity on the network.
- Broad Compatibility: Most importantly, it works flawlessly with major SCADA and PLC packages. Above all, it ensures stable connections.
- Alternatively, do you need a fixed Ethernet installation? Discover the ANC-100e.
✅ Fully Compatible with Windows 10 & Windows 11
$995.00
The Modern USB to DH+ Converter Cable for Industrial Automation
ANC-120e — Direct Replacement for the Obsolete Allen-Bradley 1784-U2DHP
Troubleshooting and programming legacy Allen-Bradley controllers shouldn’t require antique laptops or overpriced used hardware. The ANC-120e is a high-performance USB to DH+ converter cable engineered for maintenance engineers and field technicians to connect modern Windows 10 & 11 PCs directly to PLC-5 and SLC 5/04 processors.
Full Windows 10/11 64-bit compatibility at 1/3 the cost of obsolete surplus cables without driver instability.
No PCI/ISA slots, desktop towers, or virtual machines needed. Connects directly via any standard USB port.
True Data Highway Plus (DH+) speed and protocol support up to 230.4 kbps—not limited to DH-485 serial.
| Feature / Specification | Automation Networks ANC-120e | Allen-Bradley 1784-U2DHP (Legacy) |
| Operating System Support | ✅ Windows 10 & 11 (32/64-bit Verified) | ❌ Legacy OS (Windows XP / Windows 7 only) |
| RSLinx & Programming Software | ✅ RSLogix 5 & RSLogix 500 via RSLinx Classic | Complex / Discontinued proprietary drivers |
| Network Baud Rates & Auto-Detect | ✅ 57.6k, 115.2k & 230.4k (Auto-Detected) | Manual software configuration required |
| SCADA / HMI Compatibility | ✅ FactoryTalk, Ignition, Kepware, Wonderware | Limited to older Rockwell architecture |
| Power Supply Required | ✅ USB Bus-Powered (No external supply) | USB Powered |
| Availability & Lifecycle | ✅ In Stock – Brand New from Manufacturer | ❌ Obsolete / Discontinued (Surplus only) |
| Price | ✅ $995 USD | $3,000+ USD (Used / As-is market) |
| Warranty & Support | ✅ Lifetime Warranty & Full Tech Support | ❌ None (Third-party resellers) |
Key Technical Advantages of the ANC-120e USB to DH+ Converter Cable
- Seamless RSLinx Classic Integration: Communicates via standard RSLinx drivers (Remote Devices via Linx Gateway) without requiring complex COM port redirection or obsolete 16-bit virtual environments.
- Full PLC-5 & SLC 5/04 Support: Perform online edits, program uploads, downloads, and real-time data monitoring using official Rockwell RSLogix 5 and RSLogix 500 programming software.
- Smart Auto-Baud Detection: Automatically syncs to DH+ network speeds of 57.6 kbps, 115.2 kbps, or 230.4 kbps upon connection, eliminating manual switch guessing on site.
- Field-Ready Portability: Draws power directly from the host PC’s USB port. Compact design fits easily in any service technician’s tool bag.
- Risk-Free Guarantee: Includes Lifetime Hardware Warranty, 30-day money-back satisfaction guarantee, and dedicated technical support.
Need a reliable, modern USB to DH+ converter cable for your PLC maintenance laptop?
Order Your ANC-120e TodayOverview: Premium ANC-120e Converter
The Automation Networks ANC-120e converter is a cost-effective, high-performance 1784-U2DHP alternative. Moreover, this “pocket-sized” device seamlessly bridges modern Windows PCs with legacy Allen-Bradley DH+ networks. As a result, it serves as the ultimate drop-in replacement. Therefore, engineers can troubleshoot systems with zero hassle.
Why Choose This Converter?
Because older cards are obsolete, finding a reliable replacement is crucial. Consequently, this device provides a perfect, industrial-grade solution. Furthermore, it optimizes your maintenance budget.
Highlights & Key Features
Clearly, upgrading brings many advantages. For instance, consider these highlights:
- 100% Compatible: First of all, it is a highly cost-effective alternative to the discontinued hardware. Undoubtedly, it is the best option available.
- Modern OS Support: Second, it is supported on Windows 10 and Windows 11. Meanwhile, it maintains backward compatibility with legacy systems.
- Seamless Integration: Third, it works natively with RSLinx Classic. Consequently, it is fully compatible with RSLogix and FactoryTalk View.
- Auto-Baud Detection: In addition, it automatically detects network speeds. Furthermore, this eliminates manual configuration completely.
- Highly Portable: Finally, it is USB-powered and pocket-sized. In short, the ANC-120e converter is the perfect tool for field engineers.
Independent Industry Review
Watch Shawn Tierney from The Automation Blog demonstrate the seamless setup and performance of the ANC-120e on a live DH+ network.
“In today’s episode of The Automation Podcast I take a look at the ANC-120e USB to Data Highway Plus converter… Now you may be asking yourself why the folks over at Automation Networks would release a USB to DH+ converter when Rockwell already makes the 1784-U2DHP? Well if you haven’t looked lately…”
Seamless Network Topology

Yes, absolutely. The ANC-120e is widely recognized as the premier, cost-effective alternative to the discontinued and highly expensive Allen-Bradley 1784-U2DHP cable.
It acts as a seamless USB-to-DH+ bridge, allowing you to connect modern laptops and PCs directly to Data Highway Plus networks to program, monitor, and troubleshoot legacy PLC-5 and SLC 5/04 processors without requiring obsolete hardware.
Yes. Unlike legacy cables that struggle with modern operating systems, the ANC-120e is fully compatible with both 32-bit and 64-bit modern OS, including Windows 10 and Windows 11.
For facilities still running older infrastructure, the device also maintains full backward compatibility with legacy systems such as Windows XP, Windows 7, and Windows 8.
.
Configuration is incredibly straightforward and bypasses the need for complex, proprietary AB drivers. The ANC-120e operates by creating a virtual Ethernet-over-USB connection.
In RSLinx Classic, you simply configure the device using the standard “Remote Devices via Linx Gateway” driver. This allows RSLinx, RSLogix 5/500, and your SCADA systems to instantly recognize the DH+ nodes on the network.
Contenido del acordeón
No manual configuration is required. The ANC-120e features smart Auto-Baud detection technology.
Once connected, the converter will automatically detect and match the running speed of your existing Data Highway Plus network (57.6, 115.2, or 230.4 kbps). This ensures a true plug-and-play experience, saving you valuable setup time on the factory floor and preventing network configuration conflicts.
ANC-120e Technical Specifications
| Technical Specification | ANC-120e Details |
| Ports | USB Type A port. 1 two-pin DH+ network connector. (No clear shield connection required) 1 power connector. |
| Ethernet Communication Speeds | Full speed Controllogix Ethernet Driver |
| DH+ Communication Speeds | 57.6Kb, 115.2 Kb, 230.4Kb |
| Enclosure rating | Meets IP30 standard |
| External power supply | 5.00 to 6 VDC / 1A. |
| Maximum average current consumption | 175 mA |
| Isolation voltage | 400V (continuous), tested at 2000V for 60 s |
| Typical Power Consumption | 0.5Wt |
| Maximum Power Consumption | 0.85 Wt |
| Operating Temperature | 0 to +85⁰ C |
| Storage Temperature | -20 to +100⁰ C |
| Humidity | 0 to 98% |
| Dimensions | 70mm x 19mm x 12.7mm |
ANC-120e USB to DH+ PLC Programming Cable App Notes
Download the step-by-step configuration guides (Application Notes) for your specific control system below, including Inductive Automation (Ignition), Wonderware, Kepware, and FactoryTalk.
| Company | Application Note / Manual | |
| Automation Networks | ANC-120e USB to DH+ Plus User Manual | Download PDF |
| Rockwell Automation | RSLinx Classic Configuration (USB to DH+) | Download PDF |
| Rockwell Automation | RSLinx Enterprise / FactoryTalk Linx Instructions | Download PDF |
| Rockwell Automation | SLC-5/05 MSG to SLC-5/04 on DH+ App Note | Download PDF |
| Inductive Automation | Ignition HMI to SLC through ANC-120e | Download PDF |
| Inductive Automation | Ignition HMI to PLC-5 through ANC-120e | Download PDF |
| Wonderware / AVEVA | Wonderware ABCIP DAServer Application Note | Download PDF |
| Wonderware / AVEVA | Wonderware FSGateway / OIGateway Application Note | Download PDF |
| AVEVA | AVEVA ABCIP InTouch HMI Application Note | Download PDF |
| Citect | Citect 2015 Application Note | Download PDF |
| Citect | Citect 2016 Application Note | Download PDF |
| Rockwell Automation | RSLinx Enterprise / FactoryTalk Linx Instructions (v2) | Download PDF |
| Matrikon | MatrikonOPC Server for Allen-Bradley PLCs | Download PDF |
| Kepware / IGS | IGS Ethernet/IP to DH+ App Note | Download PDF |
| PeakHMI | PeakHMI Application Note | Download PDF |
| Software Toolbox | TOP Server Application Note | Download PDF |
| Rockwell Automation | PanelView Plus (PV+) to AB Data Highway Plus | Download PDF |
| Rockwell Automation | PanelView 7 Plus to AB Data Highway Plus | Download PDF |
| Cyberlogic | DHX ControlLogix Ethernet/IP to AB DH+ | Download PDF |
| Automation Networks | HMI Configuration Guide | Download PDF |
ANC-120e: USB Ethernet/IP to DH+, Programming Cable Initial Setup Tutorial
ANC-120e USB Ethernet/IP to DH+ Alternative 1784-U2DHP RSLINX Tutorial
Device Drivers & Installation Software
The ANC-120e is fully compatible with both modern and legacy Windows operating systems. Please select your required driver below and refer to the Installation Guide for step-by-step setup instructions.